Products
MENU
  • Electric material
  • Insulating material / Industrial plastic
  • Epoxy cast resin electric device


HOME > Products > Insulating material / Industrial plastic > Thermosetting resin laminates /Line-ups
> Paper/Phenolic(Thin plate)

Insulating material / Industrial plastic

Flame retardant Paper/Phenolic(Thin plate)

RISHOLITE
PS-1251TF
▲PS-1251TF(left) and PS-1651TF

 

Application:Punching parts for such as rotary swicth must with flame retardancy



Test items Unit Treatment PS-1251TF PS-1651TF
JIS/ANSI PL-P-PF/-

PL-P-PF/-

Color Brown Black
Electrical strength
(Vertical to layer)
In oil 1 min. MV/m C-90/20/65 18 OK 18 OK
Breakdown voltage
(Vertical to layer)
In oil 1 min. MV/m C-90/20/65
Electrical strength
(Parallel to layer)
In hot oil kV O-0.5/90
Breakdown voltage
(Parallel to layer)
In hot oil kV O-0.5/90
Insulation resistance at RT C-90/20/65 105~106
(102<)
105~106
(102<)
After heat treatment C-90/20/65
+D-2/100
102~103 102~103
Volume resistivity at RT MΩ-cm C-90/20/65 5×106~5×107 5×106~5×107
After moisture treatment C-90/20/65
+C-96/40/90
106~107 106~107
Surface resistance at RT C-90/20/65 105~106 105~106
After moisture treatment C-90/20/65
+C-96/40/90
5×103~5×104 5×103~5×104
Dielectric constant
(1MHz)
at RT - C-90/20/65 3.5~4.5 3.5~4.5
After dipping treatment C-90/20/65
+D-24/23
4.0~5.0 4.0~5.0
Dissipation factor
(1MHz)
at RT - C-90/20/65 0.030~0.045 0.030~0.045
After dipping treatment C-90/20/65
+D-24/23
0.035~0.045 0.035~0.045
Flexural strength Vertical to layer MPa A 125~150
(69<)
125~150
(69<)
Parallel to layer A
Compressive strength Vertical to layer MPa A
Parallel to layer A
Tensile strength MPa A
Izod impact strength Parallel to layer J/cm A
Cleavage strength kN A
Rockwell hardness - A
Water absorption 1.6mm thick % E-24/50
+D-24/23
0.6~1.2
(3.60>)
0.6~1.2
(3.60>)
3.0mm thick E-24/50
+D-24/23
10mm thick E-24/50
+D-24/23
Appearance after heating treatment 2 hours A 130 OK
(120℃)
130 OK
(120℃)
Specific gravity - A 1.35~1.45
(1.25-1.50)
1.35~1.45
(1.25-1.50)
Acetone resistance - A OK
OK
Flame resistance UL - E-168/70

94V-0

equiv.

94V-0

equiv.

Punching workability A 40~80 40~80
*The above figures show the standard properties and guaranteed value is showed in parentheses
*Test method : JIS K-6911
*Treatment condition
A=Accepted state, C=Constant Temperature and humidity , D=Dipping in water E=Electric heating , O=Oil dipping
Starting from the left figures show Time(h)/Temeperature(℃)/Humidity(%)
Specifications and dimension
Thickness(mm) 0.8~3.0
Standad dimension
(mm)
1000×1000
1000×1200
1000×1500
1000×2000
1200×2000
Thickess
tolerance
(mm)
0.5
0.6
0.8 ±0.10
1.0 ±0.10
1.2 ±0.13
1.5 ±0.13
1.6 ±0.15
2.0 ±0.15
2.5 ±0.20
3.0 ±0.20
4.0
5.0
6.0
8.0
10.0
12.0
15.0
16.0
18.0
20.0
25.0
30.0
35.0
40.0
50.0
75.0
100.0
*Minimum quantity of order would be quoted according to product