Products
MENU
  • Electric material
  • Insulating material / Industrial plastic
  • Epoxy cast resin electric device


HOME > Products > Insulating material / Industrial plastic > Thermosetting resin laminates /Line-ups
> Glass woven & Glass nonwonen composite/Phenolic laminates PS-3753

Insulating material / Industrial plastic

Glass woven & Glass nonwonen composite/Phenolic laminates PS-3753

RISHOLITE
PS-3753 Application:Automotive electric component with heavy flame retardance


Test items Unit Treatment PS-3753
Electrical strength
(Vertical to layer)
In oil 1 min. MV/m C-90/20/65 -
Breakdown voltage
(Vertical to layer)
In oil 1 min. MV/m C-90/20/65 -
Electrical strength
(Parallel to layer)
In hot oil kV O-0.5/90 -
Breakdown voltage
(Parallel to layer)
In hot oil kV O-0.5/90 -
Insulation resistance at RT C-90/20/65 105~107
After heat treatment C-90/20/65
+D-2/100
103~105
Volume resistivity at RT MΩ-cm C-90/20/65 105~107
After moisture treatment C-90/20/65
+C-96/40/90
105~107
Surface resistance at RT C-90/20/65 104~106
After moisture treatment C-90/20/65
+C-96/40/90
104~106
Dielectric constant
(1MHz)
at RT - C-90/20/65 4.0~4.8
After dipping treatment C-90/20/65
+D-24/23
4.2~5.0
Dissipation factor
(1MHz)
at RT - C-90/20/65 0.022~0.028
After dipping treatment C-90/20/65
+D-24/23
0.024~0.030
Flexural strength Vertical to layer MPa A 200~500
Parallel to layer -
Compressive strength Vertical to layer MPa A -
Parallel to layer -
Tensile strength MPa A -
Izod impact strength Parallel to layer J/cm A -
Cleavage strength kN A -
Rockwell hardness - A M.85~95
Water absorption 1.5mm Thick % E-24/50
+D-24/23
0.20~0.50
10mm Thick E-24/50
+D-24/23
-
Appearance after heating treatment 2 hours A 180 OK
Hot flexural strength retention % A -
Specific gravity - A 1.70~2.00
Tracking resistance DIN Drop A -
Acetone resistance - A OK
Flame retardance UL - E-168/70 94V-0
Arc resistance sec. A 180~190
Tg DMA A
*JRMA qualification
(*Japan Railway rollingstock & Machinery Association)
Flame retardance
(3mm thick)
*The above figures show the standard properties and guaranteed value is showed in parentheses
*Test method : JIS K-6911
*Treatment condition
A=Accepted state, C=Constant Temperature and humidity , D=Dipping in water E=Electric heating , O=Oil dipping
Starting from the left figures show Time(h)/Temeperature(℃)/Humidity(%)
Specifications and dimension
Thickness(mm) 0.8~2.0
Standad dimension
(mm)
1000×1000
1000×1200
1000×1500
1000×2000
1200×2000
Thickess
tolerance
(mm)
0.5
0.6
0.8 ±0.15
1.0 ±0.15
1.2 ±0.20
1.5 ±0.20
1.6 ±0.23
2.0 ±0.25
2.5
3.0
4.0
5.0
6.0
8.0
10.0
12.0
15.0
16.0
18.0
20.0
25.0
30.0
35.0
40.0
50.0
75.0
100.0
*Minimum quantity of order would be quoted according to product