HOME > Products > Insulating material / Industrial plastic > Thermosetting resin laminated Tube & Rod
> Cotton/Phenolic laminated tube PR-2123
Cotton/Phenolic laminated tube PR-2123
Application:Graphite / Molybdenum containing material for anti-wear application |
 |
Size
Bore tolerance
Outside diameter tolerance |
|
Test items |
Unit |
Treatment |
PR-2123 |
JIS (ANSI) |
- |
Base material |
Sheeting |
Resin |
Phenolic |
Electrical strength
(Vertical to layer 1 min. in oil) |
MV/m |
C-90/20/65 |
Not fit for electric application |
Breakdown voltage
(Dissipation factor 1 min. in oil) |
MV/m |
Electrical strength
(Parallel to layer 1min. in oil ) |
kV/15mm |
Breakdown voltage
(Parallel to layer 1min. in oil) |
Insulation resistance |
MΩ |
Dielectric constant(60Hz) |
- |
Dissipation factor(60Hz) |
- |
Flexural strength
(Vertical to layer) |
MPa |
A |
147~215 |
Flexural modulus
(Vertical to layer) |
3,920~5,880 |
Compressive strength
(Parallel to layer) |
137~176 |
Tensile strength
(Parallel to layer) |
68~108 |
Cleavage strength |
kN |
3.92~5.88 |
Appearnce
after 2hours heat treatment |
℃ |
130℃ OK |
Water absorption |
% |
E-24/50
+D-24/23 |
0.6~1.0 |
Specific gravity |
- |
A |
1.2~1.4 |
*Test method : JIS K-6911
*Treatment condition
A=Accept state, C=Constant Temperature and humidity , D=Dipping in water E=Electric heating , O=Oil dipping
Starting from the left figures show Time(h)/Temeperature(℃)/Humidity(%)
※The above figures do not show guaranteed value but one of test results . |