HOME > Products > Insulating material / Industrial plastic > Thermosetting resin laminates /Line-ups
> Glass roving & Glass nonwoven cpmposite/Epoxy laminates ES-3440
Glass roving & Glass nonwoven cpmposite/Epoxy laminates ES-3440
 |
Application:Mechanical parts |
Test items |
Unit |
Treatment |
ES-3440 |
Electrical strength
(Vertical to layer) |
In oil 1 min. |
MV/m |
C-90/20/65 |
16 OK |
Breakdown voltage
(Vertical to layer) |
In oil 1 min. |
MV/m |
C-90/20/65 |
21~36 |
Electrical strength
(Parallel to layer) |
In hot oil |
kV |
O-0.5/90 |
9 OK |
Breakdown voltage
(Parallel to layer) |
In hot oil |
kV |
O-0.5/90 |
35~45 |
Insulation resistance |
at RT |
MΩ |
C-90/20/65 |
106~108 |
After heat treatment |
C-90/20/65
+D-2/100 |
104~105 |
Volume resistivity |
at RT |
MΩ-cm |
C-90/20/65 |
108~1010 |
After moisture treatment |
C-90/20/65 +C-96/40/90 |
107~109 |
Surface resistance |
at RT |
MΩ |
C-90/20/65 |
107~109 |
After moisture treatment |
C-90/20/65 +C-96/40/90 |
106~107 |
Dielectric constant
(1MHz) |
at RT |
- |
C-90/20/65 |
4.5~5.5 |
After dipping treatment |
C-90/20/65
+D-24/23 |
4.6~5.6 |
Dissipation factor
(1MHz) |
at RT |
- |
C-90/20/65 |
0.010~0.014 |
After dipping treatment |
C-90/20/65
+D-24/23 |
0.011~0.015 |
Flexural strength |
Vertical to layer |
MPa |
A |
440~540 |
Parallel to layer |
480~580 |
Compressive strength |
Vertical to layer |
MPa |
A |
350~450 |
Parallel to layer |
330~430 |
Tensile strength |
MPa |
A |
300~400 |
Izod impact strength |
Parallel to layer |
J/cm |
A |
13~17 |
Cleavage strength |
kN |
A |
6~9 |
Rockwell hardness |
|
- |
A |
M.100~110 |
Water absorption |
1.5mm Thick |
% |
E-24/50
+D-24/23 |
- |
10mm Thick |
E-24/50
+D-24/23 |
0.02~0.05 |
Appearance after heating treatment |
2 hours |
℃ |
A |
180 OK
(180) |
Hot flexural strength retention |
% |
A |
120℃ 10< |
Specific gravity |
- |
A |
1.80~2.00 |
Tracking resistance |
IEC |
V |
A |
600 |
Acetone resistance |
- |
A |
OK |
Flame retardance |
UL |
- |
E-168/70 |
- |
Arc resistance |
sec. |
A |
180~190 |
Tg |
DMA |
℃ |
A |
100 |
*JRMA qualification
(*Japan Railway rollingstock & Machinery Association) |
|
Flame retardant
(3mm Thick) |
|
*The above figures show the standard properties and guaranteed value is showed in parentheses
*Test method : JIS K-6911
*Treatment condition
A=Accepted state, C=Constant Temperature and humidity , D=Dipping in water E=Electric heating , O=Oil dipping
Starting from the left figures show Time(h)/Temeperature(℃)/Humidity(%) |
Specifications and dimension
Thickness(mm) |
3~50 |
Standad dimension
(mm) |
1000×1000 |
◯ |
1000×1200 |
◯ |
1000×1500 |
◯ |
1000×2000 |
◯(3~20) |
1200×2000 |
|
Thickess
tolerance
(mm) |
|
|
0.5 |
|
0.6 |
|
0.8 |
|
1.0 |
|
1.2 |
|
1.5 |
|
1.6 |
|
2.0 |
|
2.5 |
|
3.0 |
±0.35 |
4.0 |
±0.40 |
5.0 |
±0.55 |
6.0 |
±0.60 |
8.0 |
±0.70 |
10.0 |
±0.80 |
12.0 |
±0.90 |
15.0 |
±1.10 |
16.0 |
±1.10 |
18.0 |
±1.30 |
20.0 |
±1.30 |
25.0 |
±1.40 |
30.0 |
±1.50 |
35.0 |
±1.60 |
40.0 |
±1.70 |
50.0 |
±1.90 |
75.0 |
|
100.0
|
|
|
*Minimum quantity of order would be quoted according to product |